Innovation Electronic Co.,Ltd

Innovation Electronic Co.,Ltd Use our Machine To Make Your Weighing and Packing Line Easier, Faster and More Cost Saving!

Manufacturer from China
Site Member
8 Years
Home / Products / Static Charging Equipment /

DC506 30KV 60KV Grey Static Charge Generator Electrostatic charging For Wood Pressing lamination 100V~240VAC

Contact Now
Innovation Electronic Co.,Ltd
City:hangzhou
Province/State:zhejiang
Country/Region:china
Contact Person:MissTINA LIU
Contact Now

DC506 30KV 60KV Grey Static Charge Generator Electrostatic charging For Wood Pressing lamination 100V~240VAC

Ask Latest Price
Video Channel
Brand Name :inntronic
Model Number :DC506
Place of Origin :China
MOQ :1pc
Payment Terms :T/T, Western Union
Delivery Time :Negotiation
Price :Negotiable
Input Voltage :100V~240VAC
Max Input Power :200 W
Output Voltage :30KV 60KV
Max Output Current :5mA
Max Output Power :150 W
Output Polarity :- Negative/+ Positive customize
more
Contact Now

Add to Cart

Find Similar Videos
View Product Description

60KV DC506 (Simco CM60) static Charging genrator for Wood pressing machine Input Voltage 100V~240VAC

DC506 60KV Electrostatic Charge Generator For Wood Pressing Machine replace Simco 5mA*150 W

Introduce

DC506 case type charging generator is a kind of static application equipment.

The static charging generator is composed of a static emitter (bar) and a DC high voltage power supply.

For DC high voltage power supply, provide plasma launcher(bar) of negative (or positive) high voltage,

to emit negative ions (or positive ions) and then add electronic charge(artificial charge) on an object (workpiece).

The higher the voltage, the greater the effective range. It is widely used in non-woven fabric, film, painting, printing,

flocking, sorting and biological engineering fields. It have many advantages like simple installation,

fire protection, no electric shock and stable work.

Safety Instruction

1, Please make sure that the equipment has been cut off before installation;

2, Equipment installation and operation must be performed by qualified electrical engineer;

3, Ensure that the equipment is properly grounded before the equipment is running.

This is a necessary condition of the safe and effective operation;

4, Without written permission, please do not repair the equipment without authorization,

otherwise the equipment will not be provided warranty service;

5, The troubleshooting need to be operated by professional engineer. Before checking the fault, please cut off the power supply.

Control and maintenance

The output voltage of charging generator can be proactively released to avoid unnecessary charge of

the high voltage stored in the high voltage power supply and the surrounding objects,

to minimize electromagnetic interference

1, If the signal line be controlled by an external controller, must through a relay or isolation optical coupling;

2, High precision fine-tuning booster control, the accuracy can reach 0.01KV;Keep dry, no dust, dirt and chemicals;
The problems caused by dust accumulation for a long time is beyond the scope of the warranty.

Instead of simco CM30 Chargemaster Installation:

(1) Installation

① Place device level;

② Grounding the equipment and ensure the reliability of the ground;

③ Fixed the charging bar,charging bar bracket should be insulated,

pin toward the surface which need to add static and connect the wire to the output of the charging generator;

④ Connect device to power supply(100V ~ 240V);

⑤ Cooling fan.

After the above steps, can start testing.

(2) Operation and Testing

① Power master switch;

② Power Indicator;

③ Work Indicator;

④ Temperature alarm indicator;

⑤ Door switch;

⑥ External control signal line.

Instead of simco CM30 Chargemaster Test procedures:

1. When the signal line is controlled by external device, the power supply need to be switched first,

and then use external device to control closure of signal lines.
2. Clockwise rotation switch, power indicator light, cooling fan start;
3. Work indicator light, said the work is normal;
4. The alarm indicator light indicates that the internal temperature of the equipment is too high, need to cool down.

Input Voltage 100V~240VAC
Max Input Power 200 W
Output Voltage 30 KV
Max Output Current 5mA
Max Output Power 150 W
Output Polarity - Negative/+ Positive customize
Working Temperature -15℃~50℃
Output Stability Max Load 1%
Output connector 1bit High voltage output
Voltage control Stepless pressure regulation
Remote control Support signal line remote switch control
Weight 7 kg
Size 500*400*200mm or 400*300*200mm

DC506 30KV 60KV Grey Static Charge Generator Electrostatic charging For Wood Pressing lamination 100V~240VACDC506 30KV 60KV Grey Static Charge Generator Electrostatic charging For Wood Pressing lamination 100V~240VACDC506 30KV 60KV Grey Static Charge Generator Electrostatic charging For Wood Pressing lamination 100V~240VAC

4, The final explanation right about all terms of warranty belongs to our company.4, The final explanation right about all terms of warranty belongs to our company.